pregleda

Asimetrični ciklični tajmer Samwha-Dsp DRV-09D


Cena:
3.000 din
Stanje: Nekorišćen
Garancija: Ne
Isporuka: AKS
BEX
City Express
Pošta
CC paket (Pošta)
DExpress
Post Express
Lično preuzimanje
Plaćanje: Tekući račun (pre slanja)
Pouzećem
Lično
Grad: Vršac,
Vršac
Prodavac

djuka76 (1192)

100% pozitivnih ocena

Pozitivne: 2168

  Pošalji poruku

Svi predmeti člana


Kupindo zaštita

Jačina struje: 6
Proizvedeno u : Aziji
Vrste sklopki: Vremenske

P18
Description
General
The DRV-09D, DRV-09 flasher relay is designed to be used in places (industry, residence, factory, etc. )
Where two-time (on-off) control is required.

Usage and Working Principle

Display :
lt is shown here when setting the time and counting down the set time. If the operating time is set in minutes, the right most dot on the displays will flash while the device is counting the time. The ON display is reserved for operating time and the OFF display is reserved for waiting time.

`ON` Knob:
It is used for the working time interval.
Interval 9.9 sec. , 99 sec. , 9.9 min. and can be set to 99 minutes (DRV-09D).
Interval 9.9 hours. , 99 hours. , 9.9 days. and can be set to 99 days (DRV-09)

`OFF` Knob:
It is used for the waiting time interval.
Interval 9.9 sec. , 99 sec. , 9.9 min. and can be set to 99 minutes (DRV-09D).
Interval 9.9 hours. , 99 hours. , 9.9 days. and can be set to 99 days (DRV-09).

“ t on` Knob:
lt is used to set the Working Time. The working time can be set in seconds or minutes according to the selected time interval. While setting the `t on` time, the adjusted value is shown on the `ON` display (on the upper screen). When set to off, turn off the `t on` delay, run only the ` t off` delay, and turn off the loop function.

“ t off` Knob:
lt is used to set the Waiting Time. The waiting time can be set in seconds or minutes according to the selected time interval. While setting the `t off` time, the adjusted value is shown on the `OFF` display (on the lower screen). When set to off, turn off the `t off` delay, run only the ` t on` delay, and turn off the loop function.

OUT Led:
This led lights up when the device energized the relay. (When counting the working time)

Example Operation Scenario

Let`s set it to be working (on) time:60 minutes, Waiting (off) time: 30 seconds.

To set the working time as 60 minutes, let`s turn the `ON` knob to the part that writes `D” (lt will appear as `99. ` on the upper display. ) and the ` t on` knob until see the value 60 on the screen (upper display).

To set the waiting time as 30 seconds, turn the `OFF` knob to the part that writes “99s. ` (lt will appear as “99` on the lower display. ) and the `t off` button until see the value 30 on the screen (lower display).

After this setting is made, the device first starts counting the`ON` time, the remaining value for the on time is displayed on the `ON` display and the `OUT` led lights up, the relay output is at the 3(NO) contact. When the `ON` time expires, the device starts counting the `OFF` time, the remaining value for the off time is displayed on the `OFF`display and the `OUT` led turns off, the relay output is in contact number 1(NC). The device continues to operate as described above until its power is cut off.

NOTE:
1- lf the time interval is changed with the `ON`and / or `OFF` knobs while the device is energized, the device must be de-energized and re-energized in order for the changed time interval to be valid.

2- If the time is changed with the `t on` and/or `t off” knobs while the device is counting time, the device continues to count the new set time.

Maintenance

Switch off the device and release from connections. Clean the trunk of device with a swab. Don’t use any conductor or chemical
might damage the device. Make sure device works after cleaning

Warnings

-Please use the device according to the manual.
-Don’t use the device in wet.
-Include a switch and circuit breaker in the assembly.
-Put the switch and circuit breaker nearby the device, operator can reach easily.
-Mark the switch and circuit breaker as releasing connection for device.

Specifications

Operating Voltage. .. .. .. .. .. .. :(A1-A2)100-240VAC
(A2-A3)12VAC/DC(A2(-), A3(+))
Operating Frequency. .. .. .. : 50/60 Hz.
Operating Power. .. .. .. .. .. .. .. : 6VA
Operating Temperature. .: -20° C. .. .. +55° C
Time interval. .. .. .. .. .. .. .: 0.1sec, - 99min. (DRV-09D)
0.1hours - 99days(DRV-09)
Display: .. .. .. .. .. .. .. .. .. .. .. .. .: 2x2 LED Display, 1x LED.
Connection Type. .. .. .. .. .: Terminal connection
Weight. .. .. .. .. .. .. .. .. .. .. .. .. .. .: Max.80gr.
Contact. .. .. .. .. .. .. .. .. .. :5A/250V AC (Resistive Load)
Mounting. .. .. .. .. .. .. .. .. .. .. : Assembled on the din rail
Operating Altitude. .. .. .. .. .: up to 2000meter
Cable Diameter. .. .. .. .. .. .. .. .. : 2,5mm²

VAŽNO!!!
1.ZA SLANJE PREPORUČENOG PISMA I CC POŠILJKE(PAKET)POTREBNO JE UNAPRED UPLATITI NOVAC!
2.NE ŠALJEM U INOSTRANSTVO!
3.NA KOSOVO I METOHIJU ŠALJEM SAMO POSTEXPESS-OM!
4.ZAMOLIO BIH POTENCIJALNE KUPCE DA PRE OBAVLJENE KUPOVINE BUDU SIGURNI DA IM PREDMET TREBA I DA ĆE GA PLATITI.ZBOG POVRAĆAJA PROVIZIJE,MORAĆU DA DAJEM NEGATIVNE OCENE!
5.UKOLIKO ČLAN KUPINDA IMA MANJE OD 10 POZITIVNIH OCENA OBAVEZNA JE UPLATA PRE SLANJA ROBE.
6.UKOLIKO ČLAN KUPINDA IMA NEGATIVNE OCENE OBAVEZNA JE UPLATA PRE SLANJA ROBE.

Predmet: 76577209
P18
Description
General
The DRV-09D, DRV-09 flasher relay is designed to be used in places (industry, residence, factory, etc. )
Where two-time (on-off) control is required.

Usage and Working Principle

Display :
lt is shown here when setting the time and counting down the set time. If the operating time is set in minutes, the right most dot on the displays will flash while the device is counting the time. The ON display is reserved for operating time and the OFF display is reserved for waiting time.

`ON` Knob:
It is used for the working time interval.
Interval 9.9 sec. , 99 sec. , 9.9 min. and can be set to 99 minutes (DRV-09D).
Interval 9.9 hours. , 99 hours. , 9.9 days. and can be set to 99 days (DRV-09)

`OFF` Knob:
It is used for the waiting time interval.
Interval 9.9 sec. , 99 sec. , 9.9 min. and can be set to 99 minutes (DRV-09D).
Interval 9.9 hours. , 99 hours. , 9.9 days. and can be set to 99 days (DRV-09).

“ t on` Knob:
lt is used to set the Working Time. The working time can be set in seconds or minutes according to the selected time interval. While setting the `t on` time, the adjusted value is shown on the `ON` display (on the upper screen). When set to off, turn off the `t on` delay, run only the ` t off` delay, and turn off the loop function.

“ t off` Knob:
lt is used to set the Waiting Time. The waiting time can be set in seconds or minutes according to the selected time interval. While setting the `t off` time, the adjusted value is shown on the `OFF` display (on the lower screen). When set to off, turn off the `t off` delay, run only the ` t on` delay, and turn off the loop function.

OUT Led:
This led lights up when the device energized the relay. (When counting the working time)

Example Operation Scenario

Let`s set it to be working (on) time:60 minutes, Waiting (off) time: 30 seconds.

To set the working time as 60 minutes, let`s turn the `ON` knob to the part that writes `D” (lt will appear as `99. ` on the upper display. ) and the ` t on` knob until see the value 60 on the screen (upper display).

To set the waiting time as 30 seconds, turn the `OFF` knob to the part that writes “99s. ` (lt will appear as “99` on the lower display. ) and the `t off` button until see the value 30 on the screen (lower display).

After this setting is made, the device first starts counting the`ON` time, the remaining value for the on time is displayed on the `ON` display and the `OUT` led lights up, the relay output is at the 3(NO) contact. When the `ON` time expires, the device starts counting the `OFF` time, the remaining value for the off time is displayed on the `OFF`display and the `OUT` led turns off, the relay output is in contact number 1(NC). The device continues to operate as described above until its power is cut off.

NOTE:
1- lf the time interval is changed with the `ON`and / or `OFF` knobs while the device is energized, the device must be de-energized and re-energized in order for the changed time interval to be valid.

2- If the time is changed with the `t on` and/or `t off” knobs while the device is counting time, the device continues to count the new set time.

Maintenance

Switch off the device and release from connections. Clean the trunk of device with a swab. Don’t use any conductor or chemical
might damage the device. Make sure device works after cleaning

Warnings

-Please use the device according to the manual.
-Don’t use the device in wet.
-Include a switch and circuit breaker in the assembly.
-Put the switch and circuit breaker nearby the device, operator can reach easily.
-Mark the switch and circuit breaker as releasing connection for device.

Specifications

Operating Voltage. .. .. .. .. .. .. :(A1-A2)100-240VAC
(A2-A3)12VAC/DC(A2(-), A3(+))
Operating Frequency. .. .. .. : 50/60 Hz.
Operating Power. .. .. .. .. .. .. .. : 6VA
Operating Temperature. .: -20° C. .. .. +55° C
Time interval. .. .. .. .. .. .. .: 0.1sec, - 99min. (DRV-09D)
0.1hours - 99days(DRV-09)
Display: .. .. .. .. .. .. .. .. .. .. .. .. .: 2x2 LED Display, 1x LED.
Connection Type. .. .. .. .. .: Terminal connection
Weight. .. .. .. .. .. .. .. .. .. .. .. .. .. .: Max.80gr.
Contact. .. .. .. .. .. .. .. .. .. :5A/250V AC (Resistive Load)
Mounting. .. .. .. .. .. .. .. .. .. .. : Assembled on the din rail
Operating Altitude. .. .. .. .. .: up to 2000meter
Cable Diameter. .. .. .. .. .. .. .. .. : 2,5mm²
76577209 Asimetrični ciklični tajmer Samwha-Dsp DRV-09D

LimundoGrad koristi kolačiće u statističke i marketinške svrhe. Nastavkom korišćenja sajta smatramo da ste pristali na upotrebu kolačića. Više informacija.