W3002 Digital Temperature Controller 10A Thermostat Control Switch with Probe Sensor
Specifications:
Product model: W3002
Temperature range: -50 ° C ~ 110 ° C
Temperature control range: -50 ° C ~ 110 ° C
Temperature measurement accuracy: ±0.2 °C
Temperature control accuracy: ±0.1 °C
Input voltage: 110-230VAC
Output power: 1500W
Output type: direct output
Mounting hole distance: 73mm (aperture 4mm)
Appearance size: 60 x 45 x 31mm
Function
Setting range:
P0 Starting temperature:-50℃~110℃
P1 Stop temperature:-50℃~110℃
P2 Temperature correction:-10℃~10℃
P3 Delayed start:0~10min
Introduction to code and features:
P0 sets the startup temperature
Press the SET button to enter the internal menu. The default display is P0. Press the SET button again to set the desired start temperature with the up and down buttons.
P1 sets the stop temperature
Press the SET button to enter the internal menu. The display is P0. Press the up and down button to change to P1. Press the SET button again to set the desired stop temperature.
P2 set temperature correction
In the same way, enter the internal menu, change to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by the up and down buttons (detection temperature + correction temperature = actual temperature)
P3 set delay start
In the same way, enter the internal menu, change to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time by the up and down buttons, the unit is minute. (Note: Delay start is generally used for compressor refrigeration. If English refrigerator freezer, this value needs to be set. According to compressor back pressure, it is generally set for 3-6 minutes. If it is not used to control compressor refrigeration, it does not need to be extended. Time function, skip directly.)
Heating mode: starting temperatureCooling mode: starting temperature > stop temperature (program automatically determines cooling mode)
Common fault code
Code
Problem
Solution
888:Resetting
Waiting for normal display
LLL:Sensor open circuit
Repair or replace the sensor
HHH:sensor short circuit