W3002 Digital Temperature Controller 10A Thermostat Control Switch with Probe Sensor 
Specifications: 
Product model: W3002 
Temperature range: -50 ° C ~ 110 ° C 
Temperature control range: -50 ° C ~ 110 ° C 
Temperature measurement accuracy: ±0.2 °C 
Temperature control accuracy: ±0.1 °C 
Input power: DC24V 
Output power: 240W (24V  10A) 
Output type: direct output 
Relay on:blue LED 
Mounting hole distance: 73mm (aperture 4mm) 
 
Appearance size: 60 x 45 x 31mm 
 
Function 
	 
 
Setting range: 
 
P0 Starting temperature:-50℃~110℃ 
P1 Stop temperature:-50℃~110℃ 
P2 Temperature correction:-10℃~10℃ 
P3 Delayed start:0~10min  
  
Introduction to code and features: 
P0 sets the startup temperature 
Press the SET button to enter the internal menu. The default display is P0. Press the SET button again to set the desired start temperature with the up and down buttons. 
P1 sets the stop temperature 
Press the SET button to enter the internal menu. The display is P0. Press the up and down button to change to P1. Press the SET button again to set the desired stop temperature. 
P2 set temperature correction 
In the same way, enter the internal menu, change to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by the up and down buttons (detection temperature + correction temperature = actual temperature) 
P3 set delay start 
In the same way, enter the internal menu, change to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time by the up and down buttons, the unit is minute. (Note: Delay start is generally used for compressor refrigeration. If English refrigerator freezer, this value needs to be set. According to compressor back pressure, it is generally set for 3-6 minutes. If it is not used to control compressor refrigeration, it does not need to be extended. Time function, skip directly.) 
Heating mode: starting temperatureCooling mode: starting temperature > stop temperature (program automatically determines cooling mode) 
Common fault code 
 
Code 
	 
 
Problem 
	 
 
Solution 
 
888:Resetting 
	 
 
Waiting for normal display 
 
LLL:Sensor open circuit 
	 
 
Repair or replace the sensor 
 
HHH:sensor short circuit