# Merač nivoa CO2 Autopilot i dodatna elektronika/kontroler
# Precizno podešavanje maksimalnog nivoa CO2 aktivira alarm i kontroler pokreće Vaše ventilatore za unos svežeg vazduha u prostoriju.
# Više komada prodato pečurkarima u proteklih pet-šest godina.
# Uredjaj meri i temperaturu i vlažnost vazduha u prostoriji, a takodje i nivo CO2 (uglendioksid).
# Sam uredjaj poseduje mogućnost dva nivoa alarma za CO2, elektronika koristi alarm maksimalne količine (alarm 2, crveni alarm), koji podešavate na željenu vrednost.
# Kalibracija uredjaja se jednostavno izvodi, a uredjaj dobijate kalibrisan na moje uslove rada (vlaga, temperatura,..)
# Na izlaz sklopke (šuko utičnica na kontroleru) moguće priključiti potrošač do 10A potrošnje, za jače potrošače možete priključiti dodatnu sklopku snage.
# Nivo CO2 pri kojima će se sklopka uključivati i pokretati ventilator-e možete detaljno digitalno podešavati.
# Kontroler je odvojen galvanski od uredjaja kvalitetnim optičkim komponentama, a samo uključenje ventilatora je izvedeno relejima.
# Vaše je samo da u utičnice sklopki uključite ventilatore koji će ubacivati svež vazduh i eventualno promenite vrednost za alarm (ja podešavam alarm na 1000ppm).
# Takodje je preporuke da se uredjaj priključi preko kvalitetnog automatskog osigurača od 16A.
# Napajanje za uredjaj je u sklopki/kontroleru.
Tehničke karakteristike mernog uredjaja:
Technical Data
General
Display ..............................................................LCD display
Measured values ..............................................Carbon dioxide, temperature and relative humidity
Calculated values..............................................Ventilation rate
Measurement interval........................................approx. 5 seconds
Warm up phase ................................................2000 ppm +/- 7% of
the reading)
Repeatability ....................................................+/- 20 ppm (at 400 ppm)
Temperature influence/°C (reference 25°C) ....+/- 2 ppm or +/- 0.2% of the reading
Air pressure influence/mmHg............................+/- 0.13 % of the reading
Temperature measurement range
Recommended measurement time ..................approx. 20 - 30 minutes
Measurement range..........................................0 - 50 °C/32 - 122 °F
Resolution ........................................................0.1°
Accuracy ..........................................................+/- 1°C / +/- 2°F (in direct air flow +/- 1.5°C)
Measurement range for relative humidity
Recommended measurement time ..................approx. 5 minutes
Measurement range..........................................20 to 90% rel. air humidity
Resolution ........................................................1 % relative air humidity
Accuracy ..........................................................+/- 5% rel. air humidity at 23 °C)
Ambient conditions
Operating temperature......................................0 to +50°C
Relative humidity: ............................................< 95% (non-condensing)
Storage temperature ........................................-20°C to +60 °C
Max. operating altitude......................................3000 m