pregleda

Digitalni termostat STC-3000


Cena:
2.000 din
Želi ovaj predmet: 1
Stanje: Nekorišćen
Garancija: Ne
Isporuka: Post Express
Lično preuzimanje
Plaćanje: Tekući račun (pre slanja)
Pouzećem
Lično
Grad: Vršac,
Vršac
Prodavac

djuka76 (1192)

100% pozitivnih ocena

Pozitivne: 2168

  Pošalji poruku

Svi predmeti člana


Kupindo zaštita

Proizvedeno u : Aziji

P08
Description:
Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration; Refrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.

Specification:
Front panel size: 75x34.5(mm)
Mounting size: 71x29(mm)
Product size: 75x34.5x85(mm)
Sensor length: 1 meter (include the probe)
Technical Parameters: Temperature measuring range: -50-99 Celsius
Accuracy: 0.1 Celsius
Sensor error delay: 1 minute
Power supply: AC220V
Power consumption: 3w
Sensor: NTC sensor(IPC)
Relay contact capacity: Cool (10A/220VAC); Heat (10A/220VAC)
Ambient temperature: 0-60 Celsius
Storage temperature: -30-75 Celsius
Relative humidity: 20-85%(No condensate)
Indicator light status instruction
Indicator light

Function
Cool indicator light
On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay
Heat indicator light
On: heating starts;Off:heating stops
Set indicator light On:parameter setting status

Key operation instruction:

1. View parameter method: When the controller is working normally, press and release the “▲” button once, display the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds return to normal temperature display state

2. Set the parameter method

When the controller is working normally, press and hold the “S” button for more than 3 seconds to enter the modified parameter mode,

The indicator light is on, and the digital tube displays the code `F1` of the first menu item.

Press “▲” or “▼” to scroll up or down the menu item and display the menu code, press “S”

The key displays the parameter setting value of the current menu. Hold down the “S” key and press and hold “▲” or “

the key can be adjusted up or down and the parameter setting value of the current menu is displayed, while holding down `S` and `▲`

The key or “▼” key can quickly up or down and display the parameter settings of the current menu.

After the completion, press and release the power button to save the parameter modification and return to the normal temperature display state.

If there is no key operation within 0 seconds, the parameter modification will not be saved and return to the normal display state.

“Er” is displayed if an error occurs while saving the parameter, and returns to the normal display state after 3 seconds.

3.Repair system data

When the machine is powered on, first check whether the parameter setting is normal. If the check is wrong, it will display “ER”. Pressing any key at this time will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.



Operation instruction:

Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off” status, press and hold “ ” key for 3s can turn on the controller.

Under the controller normal working status, screen displays the current temperature value; also the controller can also switch the working mode between heating and cooling.

Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value + difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool indicator light on, and refrigerating relay disconnects.

System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.



Menu instruction:

Code


Function


Set range


Default

F1


Temperature set value


-50~99°


10°

F2


Difference set value


1~10°




F3


Compressor delay time


1~10 minutes


3 minutes

F4


Temperature calibration value


-10°~10°




F5


Fainthearted /Celsius switching


Set range


0/1





Error description:

Alarm when sensor error: Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.

Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.



Safety Regulations

★Danger:

1.Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong

connections or overloading the relay.

2.Dangers: Prohibit connecting the wire terminals without electricity cut-off.

★Warning:

Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or

strong corrosion.

★Notice:

1.The power supply should conform to the voltage value indicated in the instruction.

2.To avoid the interference, the sensor down-lead and power wire should be kept a distance.

VAŽNO!!!
1.ZA SLANJE PREPORUČENOG PISMA I CC POŠILJKE(PAKET)POTREBNO JE UNAPRED UPLATITI NOVAC!
2.NE ŠALJEM U INOSTRANSTVO!
3.NA KOSOVO I METOHIJU ŠALJEM SAMO POSTEXPESS-OM!
4.ZAMOLIO BIH POTENCIJALNE KUPCE DA PRE OBAVLJENE KUPOVINE BUDU SIGURNI DA IM PREDMET TREBA I DA ĆE GA PLATITI.ZBOG POVRAĆAJA PROVIZIJE,MORAĆU DA DAJEM NEGATIVNE OCENE!
5.UKOLIKO ČLAN KUPINDA IMA MANJE OD 10 POZITIVNIH OCENA OBAVEZNA JE UPLATA PRE SLANJA ROBE.
6.UKOLIKO ČLAN KUPINDA IMA NEGATIVNE OCENE OBAVEZNA JE UPLATA PRE SLANJA ROBE.

Predmet: 65840697
P08
Description:
Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration; Refrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.

Specification:
Front panel size: 75x34.5(mm)
Mounting size: 71x29(mm)
Product size: 75x34.5x85(mm)
Sensor length: 1 meter (include the probe)
Technical Parameters: Temperature measuring range: -50-99 Celsius
Accuracy: 0.1 Celsius
Sensor error delay: 1 minute
Power supply: AC220V
Power consumption: 3w
Sensor: NTC sensor(IPC)
Relay contact capacity: Cool (10A/220VAC); Heat (10A/220VAC)
Ambient temperature: 0-60 Celsius
Storage temperature: -30-75 Celsius
Relative humidity: 20-85%(No condensate)
Indicator light status instruction
Indicator light

Function
Cool indicator light
On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay
Heat indicator light
On: heating starts;Off:heating stops
Set indicator light On:parameter setting status

Key operation instruction:

1. View parameter method: When the controller is working normally, press and release the “▲” button once, display the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds return to normal temperature display state

2. Set the parameter method

When the controller is working normally, press and hold the “S” button for more than 3 seconds to enter the modified parameter mode,

The indicator light is on, and the digital tube displays the code `F1` of the first menu item.

Press “▲” or “▼” to scroll up or down the menu item and display the menu code, press “S”

The key displays the parameter setting value of the current menu. Hold down the “S” key and press and hold “▲” or “

the key can be adjusted up or down and the parameter setting value of the current menu is displayed, while holding down `S` and `▲`

The key or “▼” key can quickly up or down and display the parameter settings of the current menu.

After the completion, press and release the power button to save the parameter modification and return to the normal temperature display state.

If there is no key operation within 0 seconds, the parameter modification will not be saved and return to the normal display state.

“Er” is displayed if an error occurs while saving the parameter, and returns to the normal display state after 3 seconds.

3.Repair system data

When the machine is powered on, first check whether the parameter setting is normal. If the check is wrong, it will display “ER”. Pressing any key at this time will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.



Operation instruction:

Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off” status, press and hold “ ” key for 3s can turn on the controller.

Under the controller normal working status, screen displays the current temperature value; also the controller can also switch the working mode between heating and cooling.

Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value + difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool indicator light on, and refrigerating relay disconnects.

System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.



Menu instruction:

Code


Function


Set range


Default

F1


Temperature set value


-50~99°


10°

F2


Difference set value


1~10°




F3


Compressor delay time


1~10 minutes


3 minutes

F4


Temperature calibration value


-10°~10°




F5


Fainthearted /Celsius switching


Set range


0/1





Error description:

Alarm when sensor error: Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.

Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.



Safety Regulations

★Danger:

1.Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong

connections or overloading the relay.

2.Dangers: Prohibit connecting the wire terminals without electricity cut-off.

★Warning:

Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or

strong corrosion.

★Notice:

1.The power supply should conform to the voltage value indicated in the instruction.

2.To avoid the interference, the sensor down-lead and power wire should be kept a distance.

65840697 Digitalni termostat  STC-3000

LimundoGrad koristi kolačiće u statističke i marketinške svrhe. Nastavkom korišćenja sajta smatramo da ste pristali na upotrebu kolačića. Više informacija.